Carbon free energy for Google Cloud regions

In choosing which Google Cloud region to host your application, there are multiple considerations:

  • Latency to your end users can be different from one region to the next.
  • The price of services differs from region to region.
  • The electricity used to power your application might have a different carbon intensity.

This document explains how to include carbon emissions characteristics into the location choice for your Google Cloud services.

A carbon-free cloud for our customers

To power each Google Cloud region, we use electricity from the grid where the region is located. This electricity generates more or less carbon emissions (gCO2eq), depending on the type of power plants generating electricity for that grid and when we consume it. We recently set a goal to match our energy consumption with carbon-free energy (CFE), every hour and in every region by 2030.

As we work towards our 2030 goal, we want to empower our customers to leverage our 24/7 carbon free energy efforts and consider the carbon impact of where they locate their applications. To characterize each region we use a metric: "CFE%". This metric is calculated for every hour and tells us what percentage of the energy we consumed during an hour that is carbon-free, based on two elements:

  1. The generation feeding the grid at that time (which power plants are running)
  2. Google-attributed clean energy produced onto that grid during that time.

We aggregate the available average hourly CFE percentage for each Google Cloud region for the year and have provided the 2024 data below.

Understanding the data

Google CFE%: This is the average percentage of carbon free energy consumed in a particular location on an hourly basis, while taking into account the investments we have made in carbon-free energy in that location. This means that in addition to the carbon free energy that's already supplied by the grid, we have added carbon-free energy generation in that location to reach our 24/7 carbon free energy objective. As a customer, this represents the average percentage of time your application will be running on carbon-free energy.

Grid carbon intensity (gCO2eq/kWh): This metric indicates the average operational gross emissions per unit of energy from the grid. This metric should be used to compare the regions in terms of carbon intensity of their electricity from the local grid. For regions that are similar in CFE%, this will indicate the relative emissions for when your workload is not running on carbon free energy.

Carbon data across Google Cloud regions

Google Cloud Region Location Google CFE% Grid carbon intensity
(gCO2eq/kWh)
africa-south1 Johannesburg 15% 657
asia-east1 Taiwan 17% 439
asia-east2 Hong Kong 1% 505
asia-northeast1 Tokyo 17% 453
asia-northeast2 Osaka 46% 296
asia-northeast3 Seoul 37% 357
asia-south1 Mumbai 9% 679
asia-south2 Delhi 29% 532
asia-southeast1 Singapore 4% 367
asia-southeast2 Jakarta 18% 561
australia-southeast1 Sydney 34% 498
australia-southeast2 Melbourne 39% 454
europe-central2 Warsaw 40% 643
europe-north1 Finland 98% 39 leaf icon Low CO2
europe-north2 Stockholm 100% 3 leaf icon Low CO2
europe-southwest1 Madrid 87% 89 leaf icon Low CO2
europe-west1 Belgium 84% 103 leaf icon Low CO2
europe-west2 London 79% 106 leaf icon Low CO2
europe-west3 Frankfurt 68% 276 leaf icon Low CO2
europe-west4 Eemshaven 83% 209 leaf icon Low CO2
europe-west6 Zürich 98% 15 leaf icon Low CO2
europe-west8 Milan 73% 202
europe-west9 Paris 96% 16 leaf icon Low CO2
europe-west10 Berlin 68% 276 leaf icon Low CO2
europe-west12 Turin 73% 202
me-central2 Dammam 1% 382
me-west1 Tel Aviv 7% 434
northamerica-northeast1 Montréal 99% 5 leaf icon Low CO2
northamerica-northeast2 Toronto 84% 59 leaf icon Low CO2
northamerica-south1 Mexico 19% 305
southamerica-east1 Sāo Paulo 88% 67 leaf icon Low CO2
southamerica-west1 Santiago 92% 238 leaf icon Low CO2
us-central1 Iowa 87% 413 leaf icon Low CO2
us-east1 South Carolina 31% 576
us-east2 Georgia 42% 340
us-east4 Northern Virginia 62% 323
us-south1 Dallas 94% 303 leaf icon Low CO2
us-west1 Oregon 87% 79 leaf icon Low CO2
us-west2 Los Angeles 63% 169
us-west3 Salt Lake City 33% 555
us-west4 Las Vegas 64% 357

Find the same data in a machine readable format on GitHub or as a BigQuery public dataset.

The hourly grid mix and carbon intensity data used to calculate these metrics is from Electricity Maps. This data has not been assured.

How to incorporate carbon free energy in your location strategy

Be sure to consider the other best practices for choosing resource locations like data residency requirements, latency to your end users, redundancy of the application, and price of the services available.

To use the CFE data above, here are some good ideas to get you started:

  1. Pick a cleaner region for your new applications. If you are going to run an application over time, running in the region with the highest CFE% will emit the lowest carbon emissions.
  2. Run batch jobs on the cleanest option. Batch workloads often have the benefit of planning. You should pick the region with the highest CFE% available to you.
  3. Set an organizational policy for low carbon locations. You can restrict the location of your resources to a particular Google Cloud region or subset of regions using the "Resource Location Restriction" organization policy. Dedicated "low carbon" value groups have been created to enable you to restrict locations with low carbon impact. For example, if you want to use only US-based regions, use the "Low carbon United States" (in:us-low-carbon-locations) value group.

Low carbon indicators

Some location pages on the Google Cloud website and location selectors in the Google Cloud console display " leaf icon Low CO2" next to locations that have the lowest carbon impact. The "Resource Location Restriction" organization policy offers "low carbon" value groups.

For a location to be considered "low carbon", it must belong to a region with a Google CFE% of at least 75%, or, if CFE% information is not available, a grid carbon intensity of maximum 200 gCO2eq/kWh.